Búsqueda

Limiting fire spread in National Trust properties

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071026691</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418121451.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">960114e19961001gbr||||    | |00010|eng d</controlfield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">813</subfield>
    </datafield>
    <datafield tag="100" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080080136</subfield>
      <subfield code="a">Packer, Colin</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Limiting fire spread in National Trust properties</subfield>
      <subfield code="c">Colin Packer</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">Whenever possible the National Trust seeks to avoid structural work in areas of historic value. However, this is necessary in some areas to protect life and/or to limit fire spread. The author outlines how compartmentation and the upgrading of historic doors are achieved with minimal impact on building fabric</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080620424</subfield>
      <subfield code="a">Seguridad contra incendios</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080596118</subfield>
      <subfield code="a">Edificios históricos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080603250</subfield>
      <subfield code="a">Propagación del fuego</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080614140</subfield>
      <subfield code="a">Fuegos en compartimentos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080561383</subfield>
      <subfield code="a">Arquitectura</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080562663</subfield>
      <subfield code="a">Gran Bretaña</subfield>
    </datafield>
    <datafield tag="740" ind1="0" ind2=" ">
      <subfield code="a">Fire prevention</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">Fire prevention</subfield>
      <subfield code="d">London</subfield>
      <subfield code="g">nº 293, October 1996 ; p. 30-32</subfield>
    </datafield>
  </record>
</collection>