WBGT clothing adjustments for four clothing ensembles under three relative humidity levels
<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<title>WBGT clothing adjustments for four clothing ensembles under three relative humidity levels</title>
</titleInfo>
<name type="personal" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080212902">
<namePart>Bernard, Thomas E.</namePart>
<nameIdentifier>MAPA20080212902</nameIdentifier>
</name>
<name type="corporate" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080460990">
<namePart>American Industrial Hygiene Association</namePart>
<nameIdentifier>MAPA20080460990</nameIdentifier>
</name>
<name type="corporate" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080474805">
<namePart>American Conference of Governmental Industrial Hygienists</namePart>
<nameIdentifier>MAPA20080474805</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">usa</placeTerm>
</place>
<dateIssued encoding="marc">2005</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
<form authority="marccategory">microform</form>
</physicalDescription>
<abstract>Threshold limit values for heat stress and strain are based on an upper limit wet bulb globe temperature (WBGT) for ordinary work clothes, with clothing adjustment factors (CAF) for other clothing ensembles. The purpose of this study was to determine the CAF for four clothing ensembles against a baseline of cottom work clothes and to determine what effect relative humidity may have. A climatic chamber was used to slowly increase the level of heat stress by increasing air temperature at three levels of relative humidity (20%, 50%, and 70%)</abstract>
<note type="statement of responsibility">Thomas E. Bernard... [et al]</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080585679">
<topic>Higiene industrial</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080604714">
<topic>Análisis de resultados</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080560768">
<topic>Temperatura</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080568894">
<topic>Estrés térmico</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080560799">
<topic>Termometría</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080600488">
<topic>Contaminantes físicos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080560973">
<topic>Valores TLV</topic>
</subject>
<classification authority="">872</classification>
<relatedItem type="host">
<titleInfo>
<title>Journal of occupational and environmental hygiene</title>
</titleInfo>
<originInfo>
<publisher>Cincinnati, Ohio : American Industrial Hygiene Association : American Conference of Governmental Industrial Hygienists</publisher>
</originInfo>
<part>
<text>Vol. 2, nº 5, May 2005 ; p. 251-256</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">050729</recordCreationDate>
<recordChangeDate encoding="iso8601">20080418125344.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071507046</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>