Prévention des risques pathologiques liés a l'exposition aux esters nitriques des polyols
<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<title>Prévention des risques pathologiques liés a l'exposition aux esters nitriques des polyols</title>
</titleInfo>
<titleInfo type="alternative">
<title>Travail & sécurité</title>
</titleInfo>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">fra</placeTerm>
</place>
<dateIssued encoding="marc">1983</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">fre</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
<form authority="marccategory">microform</form>
</physicalDescription>
<abstract displayLabel="Summary">Les esters nitriques des polyols, notamment le nitroclicol et le nitroglycérine, peuvent être à l'origine de troubles vasomoteurs ou cardio-vasculaires. Il est recommandé aux chefs d'établissement dont tout ou partie du personnel met en oeuvre ou manipule, même de la façon occasionnelle des esters nitriques des polyols, d'appliquer une suite de mesures par le prévention des pathologiques liés a l'exposition a ces produits explosifs</abstract>
<tableOfContents displayLabel="Contents">Recommandations adoptées par le Comité national des industries chimiques de 7 juin 1983</tableOfContents>
<note>Estas recomendaciones también aparecen publicadas en la revista "Cahiers de notes documentaires", nº 113, 4e. trimestre 1983, p. 577-579</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080605278">
<topic>Contaminantes químicos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080558291">
<topic>Explosiones</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080570484">
<topic>Riesgo laboral</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080628048">
<topic>Equipos de protección individual</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080569723">
<topic>Nitroglicerina</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080621254">
<topic>Detectores de contaminantes</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080614942">
<topic>Prevención de accidentes</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080585679">
<topic>Higiene industrial</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080588533">
<topic>Tratamiento médico</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080576615">
<topic>Medicina laboral</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080575885">
<topic>Esteres nítricos</topic>
</subject>
<classification authority="">872</classification>
<relatedItem type="host">
<titleInfo>
<title>Travail & sécurité</title>
</titleInfo>
<originInfo>
<publisher>Paris</publisher>
</originInfo>
<identifier type="local">MAP20077000314</identifier>
<part>
<text>nº 9, Septembre 1983 ; p. 506-507</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">931006</recordCreationDate>
<recordChangeDate encoding="iso8601">20080418114002.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071014778</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>