Pesquisa de referências

Placement of forearm surface EMG electrodes in the assessment of hand loading in manual tasks

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000cab a2200000   4500</leader>
    <controlfield tag="001">MAP20130025407</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20130829132100.0</controlfield>
    <controlfield tag="008">130805e20130701esp|||p      |0|||b|spa d</controlfield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
      <subfield code="d">MAP</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">875</subfield>
    </datafield>
    <datafield tag="100" ind1="1" ind2=" ">
      <subfield code="0">MAPA20130010823</subfield>
      <subfield code="a">Takala, Esa-Pekka</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Placement of forearm surface EMG electrodes in the assessment of hand loading in manual tasks</subfield>
      <subfield code="c">Esa-Pekka Takala, Risto Toivonen</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">Surface electromyography (EMG) is commonly used to study the loading of the forearm. Pro-supination movements cause surface electrodes to move in relation to the underlying muscles. We studied the effects of different electrode locations and forearm postures on the association between the EMG signals and external hand load in a laboratory experiment. Eleven subjects performed simulated work tasks with the forearm in neutral, pronated or supinated postures and with systematic variation of external load. The tasks included isometric gripping, pushing and pulling, and lifting and lowering weights. Surface EMG was recorded by six pairs of electrodes located on the forearm. The associations were studied using multiple regression models. EMG activity varied according to the forearm posture, location of electrodes and type of simulated task. Variation was lowest with a through-forearm setting of electrodes. This setting also showed the highest correlation between external loads and the EMG activity [coefficient of determination (R 2) = 0.250.66].</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="w">MAP20100019818</subfield>
      <subfield code="t">Ergonomics : the international journal of research and practice in human factors and ergonomics</subfield>
      <subfield code="d">Oxon [United Kingdom] : Taylor & Francis, 2010-</subfield>
      <subfield code="x">0014-0139</subfield>
      <subfield code="g">01/07/2013 Volumen 56 Número 7 - julio 2013 </subfield>
    </datafield>
  </record>
</collection>