Pesquisa de referências

The Energy demands of portable gas analysis system carriage during walking and running

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000cab a2200000   4500</leader>
    <controlfield tag="001">MAP20140004386</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20140204173042.0</controlfield>
    <controlfield tag="008">140204e20131202esp|||p      |0|||b|spa d</controlfield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
      <subfield code="d">MAP</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">875</subfield>
    </datafield>
    <datafield tag="245" ind1="0" ind2="4">
      <subfield code="a">The Energy demands of portable gas analysis system carriage during walking and running</subfield>
      <subfield code="c">S. Andy Sparks...[et.al]</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">The aim of this study was to evaluate the carriage of a portable gas analyser during prolonged treadmill exercise at a variety of speeds. Ten male participants completed six trials at different speeds (4, 8 and 12 km h- 1) for 40 min whilst wearing the analyser (P) or where the analyser was externally supported (L). Throughout each trial, respiratory gases, heart rate (HR), perceptions of effort and energy expenditure (EE) were measured. Significantly higher EE occurred during P12 (p = 0.01) than during L12 (855.3 ± 104.3; CI = 780.7930.0 and 801.5 ± 82.2 kcal; CI = 742.7860.3 kcal, respectively), but not at the other speeds; despite this, perceptions of effort and HR responses were unaffected. This additional EE is likely caused by alterations to posture which increase oxygen demand. The use of such systems is unlikely to affect low-intensity tasks, but researchers should use caution when interpreting data, particularly when exercise duration exceeds 30 min and laboratory-based analysers should be used where possible.</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="w">MAP20100019818</subfield>
      <subfield code="t">Ergonomics : the international journal of research and practice in human factors and ergonomics</subfield>
      <subfield code="d">Oxon [United Kingdom] : Taylor & Francis, 2010-</subfield>
      <subfield code="x">0014-0139</subfield>
      <subfield code="g">02/12/2013 Volumen 56 Número 12 - diciembre 2013 </subfield>
    </datafield>
    <datafield tag="856" ind1=" " ind2=" ">
      <subfield code="y">MÁS INFORMACIÓN</subfield>
      <subfield code="u">mailto:centrodocumentacion@fundacionmapfre.org?subject=Consulta%20de%20una%20publicaci%C3%B3n%20&body=Necesito%20m%C3%A1s%20informaci%C3%B3n%20sobre%20este%20documento%3A%20%0A%0A%5Banote%20aqu%C3%AD%20el%20titulo%20completo%20del%20documento%20del%20que%20desea%20informaci%C3%B3n%20y%20nos%20pondremos%20en%20contacto%20con%20usted%5D%20%0A%0AGracias%20%0A</subfield>
    </datafield>
  </record>
</collection>