A Critical review of glove and hand research with regard to medical glove design

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000cab a2200000   4500</leader>
    <controlfield tag="001">MAP20140019144</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20140530130414.0</controlfield>
    <controlfield tag="008">140527e20140106esp|||p      |0|||b|spa d</controlfield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
      <subfield code="d">MAP</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">875</subfield>
    </datafield>
    <datafield tag="245" ind1="0" ind2="2">
      <subfield code="a">A Critical review of glove and hand research with regard to medical glove design</subfield>
      <subfield code="c">Peter Mylon...[et.al]</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">Research from a number of areas was surveyed, including hand function; skin friction; manual performance testing; glove comfort, fit and durability; and user perception. The relevance of the research to medical glove design was discussed. It was concluded that, while an understanding has been gained of the factors that affect glove performance in general, specific application to thin rubber gloves has not been well explored. The focus in glove performance testing has also been on simple tasks such as pegboards, which do not necessarily assess the fine dexterity required in many surgical tasks. Recommendations were made for the development of a new battery of tests specific to medical gloves that would simulate real medical tasks and could produce repeatable results and have sufficient resolution to differentiate between glove types.</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="w">MAP20100019818</subfield>
      <subfield code="t">Ergonomics : the international journal of research and practice in human factors and ergonomics</subfield>
      <subfield code="d">Oxon [United Kingdom] : Taylor & Francis, 2010-</subfield>
      <subfield code="x">0014-0139</subfield>
      <subfield code="g">06/01/2014 Volumen 57 Número 1 - enero 2014 </subfield>
    </datafield>
  </record>
</collection>