Determination of the precision and accuracy of morphological measurements using the Kinect sensory : comparison with standard stereophotogrammetr
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000cab a2200000 4500</leader>
<controlfield tag="001">MAP20140020089</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20140604163718.0</controlfield>
<controlfield tag="008">140603e20140407esp|||p |0|||b|spa d</controlfield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
<subfield code="d">MAP</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">875</subfield>
</datafield>
<datafield tag="245" ind1="0" ind2="0">
<subfield code="a">Determination of the precision and accuracy of morphological measurements using the Kinect sensory</subfield>
<subfield code="b">: comparison with standard stereophotogrammetr</subfield>
<subfield code="c">B. Bonnechère...[et.al]</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">The recent availability of the Kinect sensor, a low-cost Markerless Motion Capture (MMC) system, could give new and interesting insights into ergonomics (e.g. the creation of a morphological database). Extensive validation of this system is still missing. The aim of the study was to determine if the Kinect sensor can be used as an easy, cheap and fast tool to conduct morphology estimation. A total of 48 subjects were analysed using MMC. Results were compared with measurements obtained from a high-resolution stereophotogrammetric system, a marker-based system (MBS). Differences between MMC and MBS were found; however, these differences were systematically correlated and enabled regression equations to be obtained to correct MMC results. After correction, final results were in agreement with MBS data (p = 0.99). Results show that measurements were reproducible and precise after applying regression equations. Kinect sensors-based systems therefore seem to be suitable for use as fast and reliable tools to estimate morphology.</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="w">MAP20100019818</subfield>
<subfield code="t">Ergonomics : the international journal of research and practice in human factors and ergonomics</subfield>
<subfield code="d">Oxon [United Kingdom] : Taylor & Francis, 2010-</subfield>
<subfield code="x">0014-0139</subfield>
<subfield code="g">07/04/2014 Volumen 57 Número 4 - abril 2014 </subfield>
</datafield>
</record>
</collection>